BXVHT - MIXSTD2A-100, MIXED CALIBRATION STANDARD-CAL (SUPDAT)
- MSDS: BXVHT
- Manufacturer: SPEX INDUSTRIES INC
- Product Name: MIXSTD2A-100, MIXED CALIBRATION STANDARD-CAL (SUPDAT)
- National Stock Number: 6630-00N060361
Product Identification
Product ID:MIXSTD2A-100, MIXED CALIBRATION STANDARD-CAL (SUPDAT)
MSDS Date:02/23/1994
FSC:6630
NIIN:00N060361
MSDS Number: BXVHT
Responsible Party
EDISON, NJ 08820
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 908-549-7144
Preparer: VANAJA SIVAKUMAR
Cage: 07977
Contractor
Telephone: 732-549-7144
Cage: 07977
Ingredients
NITRIC ACID; (HNO*3) (SARA 302/313) (CERCLA) (CONTAINING
CAS: 7697-37-2
RTECS: QU5775000
Fraction By Weight: 5%
OSHA PEL 2 PPM
ACGIH TLV: 2 PPM;4 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
200 PPM.
CAS: 12030-89-6
RTECS: TT3790000
Fraction By Weight: <0.1%
OSHA PEL N/K
ACGIH TLV: N/K
100 PPM.
CAS: 7439-98-7
RTECS: QA4680000
Fraction By Weight: <0.1%
OSHA PEL 10 PPM
ACGIH TLV: 10 PPM
100 PPM.
CAS: 7440-23-5
RTECS: VY0686000
Fraction By Weight: <0.1%
OSHA PEL N/K
ACGIH TLV: N/K
50 PPM.
CAS: 12057-24-8
RTECS: OJ6360000
Fraction By Weight: <0.1%
OSHA PEL N/K
ACGIH TLV: N/K
STRONTIUM. %10 PPM.
Fraction By Weight: <0.1%
OSHA PEL N/K
ACGIH TLV: N/K
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 90-95%
OSHA PEL N/K
ACGIH TLV: N/K
VIOLENT SPLATTERING.
RTECS: 9999999ZZ
EXPOS. INGEST OF LIQ WILL CAUSE IMMED PAIN
RTECS: 9999999ZZ
FATAL CAUSING SPASM, INFLAMM & EDEMA OF LARYNX &
RTECS: 9999999ZZ
SENSATION, COUGHING, WHEEZING, LARYNGITIS, SHORTNESS
RTECS: 9999999ZZ
& FULL LENGTH FACESHIELD .
RTECS: 9999999ZZ
OF AN EYE WASH IN CASE OF EMERGENCY.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SYMPS & HLTH HAZS FOR DILUTE NITRIC
ACID ARE EXPECTED TO BE LESS SEV THAN EXPOS TO CONC NITRIC ACID.
HOWEVER, SINCE NITRIC ACID IS IN SOLN AT 1% OR GREATER, HLTH HAZS
FOR CONC NITRIC ACID ARE GIVEN. C ONC NITRIC ACID MAY BE FATAL IF
TOO MUCH IS INHALED/ABSORBED THRU SKIN. CONC NITRIC ACID VAP/MIST
IS AN(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:IRRIT OF EYES, MUC MEMBS & SKIN. IN
CONT W/EYES, IT PRDCES SEV BURNS WHICH MAY RSLT IN PERM DMG &
VISUAL IMPAIRMENT. ON SKIN, LIQ/CONC VAP PRDCES IMMED, SEV &
PENETRATING BURNS; CONC SOLNS CA USE DEEP ULCERS & STAIN SKIN
BRIGHT YELLOW/YELLOWISH BROWN COLOR. VAP & MIST MAY ERODE EXPOS
TEETH W/PRLNG (ING 9)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES OCCAS LIFTING
UPPER & LOWER EYELIDS. SKIN:REMOVE CONTAM CLOTHING, THEN FLUSH
W/WATER FOR AT LEAST 15 MINUTES. WASH CLOTHING THORO BEFORE REUSE.
INHAL:MOVE TO FRESH AIR. INGEST:DO NOT INDUCE VOMITING. GET MED
ATTN IMMEDIATELY. ONLY IF VICTIM IS CONSCIOUS, GIVE LARGE AMOUNTS
OF WATER OR MILK. IF IRRITATION CONTINUES, GET MEDICAL ATTENTION
IMMEDIATELY.
Fire Fighting
Extinguishing Media:APPROPRIATE TO SURROUNDING FIRE CONDITIONS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:CONC HNO*3 IS NOT COMBUST, BUT IS STRONG
OXIDIZER & ITS HEAT OF RXN W/REDUCING AGENTS/COMBUSTS MAY CAUSE
IGNIT. CAN REACT W/METALS TO RELS FLAMM (SUPP DATA)
Accidental Release
Spill Release Procedures:VENT AREA. DILUTE SPILL W/WATER & NEUT W/SODA
ASH, LIMESTONE, ETC. WIPE UP & PUT INTO SEALED CNTNR FOR PROPER
DISP. WASH SPILL SITE OFF W/WATER AFTER MATL PICK UP IS COMPLETE.
WEAR CHEM RESIST GLASSES , GLOVES & CLTHG. WEAR NIOSH/MSHA APPRVD
RESP.
Neutralizing Agent:SODA ASH, LIMESTONE, ETC.
Handling
Handling and Storage Precautions:CONC NITRIC ACID WILL ATTACK SOME
FORMS OF PLASTICS, RUBBER & COATINGS. STORE AT ROOM TEMP. KEEP
TIGHTLY SEALED WHEN NOT IN USE.
Other Precautions:IRRITANT, OXIDIZER & CORROSIVE LIQUID. AVOID
INHALATION, INGESTION & CONTACT W/EYES & SKIN.
Exposure Controls
Respiratory Protection:WEAR NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:USE IN A CHEMICAL FUME HOOD.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(ING 12)
Other Protective Equipment:DELUGE SHOWER WHICH MEETS ANSI DESIGN
CRITERIA . WEAR CHEM RESIST CLTHG, LAB COAT. HAVE IMMED
AVAILABILITY(ING 13)
Work Hygienic Practices:WASH CAREFULLY AFTER USE.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:SOLUTION 2. EXPLO HAZ:HYDROGEN GAS. CONC HNO*3
REACTS EXPLOSIVELY W/COMBUST ORG/READILY OXIDIZABLE MATLS SUCH AS;
ALCOHOL, WOOD, TURPENTINE, METAL PWDRS, HYDROGEN SULFIDE, ETC .
MATLS TO AVOID:ALCOHOL, WOOD, TURPENTINE, METAL PWDRS, HYDROGEN
SULFIDE, ETC. CONT W/STRONG BASES WILL CAUSE (ING 8)
Chemical Properties
Spec Gravity:1
Solubility in Water:SOLUBLE
Appearance and Odor:TRANSPARENT W/ACRID ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
CONC HNO*3 IS POWERFUL OXIDIZING AGENT. IT REACTS EXPLOSIVELY W/COMBUST
ORG/READILY OXIDIZABLE MATLS SUCH AS; (SUPDAT)
Stability Condition to Avoid:ELEVATED TEMPERATURES MAY CAUSE CONTAINERS
TO BURST & LIBERATE TOXIC OXIDES OF NITROGEN.
Hazardous Decomposition Products:WILL RELEASE TOXIC NITROGEN OXIDE
FUMES & VAPORS.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . CONTACT LOCAL HAZARDOUS OR CHEMICAL WASTE DISPOSAL
AGENCY FOR REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.